Stabilizers
DHS-Series
DHS-Series Features
Digital Signal Processor
LCD Display for Parameters
Overload Protection
1:10 ratio crest factor
Natural air cooled
High Efficiency
Auto Bypass
Applications
CNC Machine Tools
Injection Molding Machines
Printing Machines
Medical Equipment
Food Processing Machines
Texttile Machines-Spinning, Weaving, Knitting, Embroidery, Garments, Manufacturing
Domestic Application, Home Appliance, Shops, Malls & Villas, All Industrial, Commercial, Residential Loads, Etc...
| MODEL | DHS1003A | DHS1253A | DHS1503A | DHS2003A | DHS2503A | DHS3003A | |
|---|---|---|---|---|---|---|---|
| Topology | DSP Controlled IGBT Based Static Voltage Stabilizer | ||||||
| Phase Sequence | Three Phase to Three Phase | ||||||
| Capacity | 100KVA | 125KVA | 150KVA | 200KVA | 250KVA | 300KVA | |
| Input | |||||||
| Nominal Voltage | 340~460 / 320~480 / 300~500 | ||||||
| Maximum rated input current per/phase 352V | 170 | 212 | 255 | 340 | 425 | 509 | |
| Maximum rated input current per/phase 332V | 180 | 226 | 271 | 340 | 425 | 509 | |
| Maximum rated input current per/phase 311V | 192 | 241 | 289 | 340 | 425 | 509 | |
| Nominal Frequency | 47Hz ~ 53Hz | ||||||
| Input circuit breaker rating | 200A 3P | 250A 3P | 400A 3P | 400A 3P | 630A 3P | 630A 3P | |
| Input circuit breaker rating | 200A 3P | 250A 3P | 400A 3P | 400A 3P | 630A 3P | 630A 3P | |
| Input circuit breaker rating | 200A 3P | 250A 3P | 400A 3P | 400A 3P | 630A 3P | 630A 3P | |
| AC Connection | Terminal block (Line L1,L2,L3, Neutral and Ground wires) Provided | ||||||
| Output | |||||||
| Nominal Voltage | 400/415/420 VAC Settable | ||||||
| Power Efficiency | typically over 98% (with 20% ~ 100% load conditions) | ||||||
| Voltage Regulation | ±1% | ||||||
| Maximum Rated output current | 144 | 180 | 217 | 289 | 361 | 433 | |
| AC connection | Terminal block (Line L1in,L2in,L3in, Neutral and Ground) Provided | ||||||
| Crest Factor | 1:10 | ||||||
| Environmental | |||||||
| Ambient Temperature | 0℃ ~ 45℃, 10% to 90% RH non-condensing | ||||||
| Cooling method | Forced Air Cooled | ||||||
| Display | |||||||
| Protections | |||||||
| Standards & Safety | Designed to meet UL 60950-1 Standards, Protection class IP 20 | ||||||
| OV /UV Cut off | Electronic cut off circuit with graded time delay for High/Low/ Missing Voltage | ||||||
| Over Load & Short-Circuit | CT based elecrtonic cut off circuit with graded time delay set @110% of rated full load current | ||||||
| Soft Switch-On | O/P Voltage never > I/P Voltage upon switch-on, before it commences full stabilization | ||||||
| Automatic Bypass | will be activated when there is a heavy surge | ||||||
| Surge Test Condition | per class 2 surge (combination wave) | ||||||
| Surge let-through voltages | 8 x 20 µs upto 40 kA wave form, L-N <460V |