BMS
BMS-RACK MASTER
RACK-MASTER BMS Features
The Master / Rack BMS Module is designed to communicate with the slave modules of 48V , connected in series.
High Speed Industrial RS232/CAN bus communication
This is acquires vital information on the individual cells of the slave module
Continuous monitoring & recording data of
Charge & discharge currents of battery bank
Individual module currents of channels
Battery pack voltage and temperature
takes necessary action to connect / disconnect to the charger / load, as required.
Intelligent Cell Balancing
Diasy Chain Communication
SOC and SOH Calculations
Onboard capacitive isolation
Open battery Connection detection
Software Integration:
Front End Application (GUI)
Data Export to MATLAB Supporting
Protections:
Over Voltage
Under Voltage
Over Current
Over Temperature
Over Load
Over Charge
Reverse
Data Logging:
Cell Voltage
Current
Temperature
Onboard temperature sensor
Inbuilt isolated DC-DC converter
Independent SB50 connector for charger connection and SB100 for Load connection
Common Applications for Electric Vehicles,UPS,EV 3 Wheeler and Laser System
| MODEL | BMS-RACK-MASTER |
|---|---|
| Configuration | |
| Battery Module Capacity(AH) | 100A |
| No.of Modules in series | 15S (51.2V Module) |
| System Operating Voltage (V) | 768 V, Nom for LiFePO4 |
| Charge / Discharge Current (A) | |
| Recommended | 50A |
| Maximum | 100A |
| Peak Discharge | 150A (2min) |
| Charge Temperature | 0℃ – 55 ℃ |
| Discharge Temperature | -20℃ – 55 ℃ |
| Communication Port | CAN 2.0 / RS 485 / Ethernet |
| Dimensions (W x D x H) mm | 3U, 19” rack |
| Protections Enabled | Battery Under Voltage, Battery Over Voltage,Short Circuit Current,Over Temperature |
| Data Acquired | |
| Total Battery Voltage (15 modules in series) | |
| Battery Current (CH & DISCH) | |
| Temperature | |
| Status Indications | Power ON,RUN,SOC,Cell balance,Battery UV,Battery OV, |
| Display | 7” Touch Screen Display |