Online UPS
DX800-Series
DX800-Series Features
DSP control technology
Single/Single Phase, Three/Single Phase models with online double conversion technology
Suitable for all kinds of loads(Resistive, Inductive and Non-Linear Loads etc)
High Overload capability (upto 150%)
Bypass dual DSP control design to enhance more reliability
Supports dual input, hot standby in series
Redundant & Parallelable with advanced parallel current sharing control technology
Cold start and mains start function
High charging capability:
2A / 4A / 6A / 8A / 10A / 12A selectable (standard)
14A / 16A / 18A / 20A / 22A / 24A selectable (options)
Standard configuration
Superior protection:
Surge
Short-Circuit
Over Voltage
Under Voltage
Over Charge
Reverse battery protection etc
Advanced Communications: RS232and USB ports(standard), SNMP,dry contacts and RS485(options), Wi-Fi card (optional)
Other Options (parallel kits, input isolation transformer, bypass isolation transformer and harmonic suppressor)
| MODEL | DX810(3:1) | DX815(3:1) | DX820(3:1) | DX830(3:1) |
|---|---|---|---|---|
| Rating Capacity | 10KVA/8kW | 15KVA/12kW | 20KVA/16kW | 30KVA/24kW |
| Input | ||||
| Input wiring | 3-Phase 5-Wire (3ϕ+N+PE) | |||
| Rated Voltage | 380/400/415 VAC | |||
| Voltage Range | 285 ~ 475 VAC | |||
| Rated Frequency | 50Hz/60Hz | |||
| Frequency Range | 40Hz~70Hz | |||
| Bypass input Voltage Range | ±25% (Settable) | |||
| Output | ||||
| Output Wiring | Single Phase 3-Wire (1ϕ+N+PE) | |||
| Rated Voltage | 220/230/240 VAC | |||
| Output Voltage Regulation | ±1% | |||
| Output Frequency | 50Hz/60Hz ±0.1% in battery mode | |||
| Power Factor | 0.8 | |||
| THDv | ≤2%(Linear Load); ≤5% (Non-Linear Load) | |||
| Crest Factor | 3:1 | |||
| Overload | 105% |
|||
| Battery | ||||
| DC Voltage | 192 VDC | |||
| No.of Batteries | 12V x 16 pcs | |||
| Charging Voltage | 216 VDC | |||
| EOD | 168 VDC | |||
| Charging Current | Default 8A (2A/4A/6A/8A/10A/12A selectable) | |||
| System | ||||
| Max No.of Parallel connections | 2 | |||
| Protections | Shor-Circuit, Overload, Over Temp, Battery Low Voltage, Under Voltage, Over Voltage and Fan Failure Protection | |||
| Communications | Standard Communications: RS232,RS485,CAN,NET,SNMP,dry contacts, and EPO | |||
| Environmental | ||||
| Operating Temperature | 0℃ ~ 40℃ | |||
| Storage Temperature | -25℃ ~ +55℃ (without Battery) | |||
| Relative Humidity | 0% ~ 95% (Non-condensing) | |||
| Altitude | ≤1000m, above 1000m, derating 1% for each additional 100m | |||
| Protection Level | IP 20 | |||
| Noise | ≤60 dB (at 1m) | |||
| Others | ||||
| Cabinet Dimensions (WxDxH)mm | 310x600x880 | 400x815x1100 | ||
| Packaged Dimensions (WxDxH)mm | 430x710x1080 | 525x925x1305 | ||
| Net Weight(kg) | 140 | 210 | 240 | 280 |
| Net Weight(kg) | 153 | 225 | 255 | 295 |
| Color | Black |