Lithium Battery Pack
LBP-204V-15AH
LBP-204V-15AH Features
Modular architecture with 2 Levels of control
Supervisory control
Slave Control
High Integrated battery Stack Slave Controller
monitoring & recording data of
Voltage
Current
Temperature
Continuous monitoring & recording data of
Charge & discharge currents of battery bank
Individual module currents of channels
Battery pack voltage and temperature
Intelligent Cell Balancing Technology
SOC and SOH Calculations
Onboard capacitive Isolation
Onboard temperature sensor
Onboard Current sensor
Additional Digital and Analog I/O
Open battery Connection detection
Fault Management and Diagnostics
Automatic Thermal Shutdown when temperature exceeds limits and over current protection
Inbuilt isolated DC-DC converter
Independent SB50 connector for charger connection and SB100 for Load connection
Common Applications for Electric Vehicles,UPS,EV 3 Wheeler and Laser System
Additional Features
Easy to disconnect Battery coneections
Status and Fault Indication LEDs
State of CHarge
Balance Enable
Over Voltage
Under Voltage
Fault Alarm
Protections:
Over Voltage
Under Voltage
Over Current
Over Temperature
Over Load
Over Charge
Reverse
Self Diagnosis and Error alarms
MODEL | LBP-204V-15AH |
---|---|
Main Features | ◎ Automatic Thermal Shutdown when temperature exceeds limits and over current protection. ◎ Inbuilt isolated DC-DC converter ◎ Independent SB75 Connector for Charger Connection ◎ SB120 Connector for Load Connection |
Technical Specifications | |
Voltage | 204V |
Resolution | 0.01V |
Accuracy | ±10mV |
Temperature | -20~85℃ |
Battery Pack Specifications | |
Battery Type (Cell Chemistry) | LFP |
Nominal Voltage | 204V |
Rated Capacity | 15AH |
Charge Voltage | 230V |
Max. Charge Current | 8A @0.5C rate |
Max. DisCharge Current | 15A @1C rate |
DisCharge Cut-off Voltage | 166V |
Operating Temperature (Charge) | 0~45℃ |
Operating Temperature (DisCharge) | -20~60℃ |
No.of Cycles | ≥2000 Cycles @80% DOD @23°C |